´ó±¦ÓéÀÖ

¸ßËÙÏßÀÂ

10G SFP+ÓÐÔ´µçÀÂ

0.0/5 rating (0 votes)

Description

F- tone¹«Ë¾×¨ÒµÑз¢ÖÆÔì10G SFP+ÓÐÔ´µçÀ¡¢10G SFP+ Active Cable,ÇкÏMSA SFF-8431, Ó¦ÓÃÓÚ10GÒÔÌ«ÍøµÈÊý¾ÝÖÐÐÄ»¥Áª³¡¾° ¡£100%ÍêÃÀ¼æÈÝȫϵÁÐÆ·ÅÆЧÀÍÆ÷,½»»»»ú,·ÓÉÆ÷,PDH/SDH´«ÊäÉ豸,EPON,GPON,10G EPON,10G GPON,WDM PON»ùÕ¾µÈµÈȫϵÁÐÉ豸

10G SFP+ÓÐÔ´µçÀÂ


SFP+ Direct Attach Active Copper Cables ,5m¡¢7m¡¢10m¡¢12m Reach

Features

  1. Support for multi-gigabit data rates up to 10.5Gbps
  2. Data rates backward compatible to 1Gbps
  3. Hot-pluggable SFP 20PIN footprint
  4. I/O Connector designed for high speed differential signal applications
  5. Improved Pluggable Form Factor(IPF) compliant for enhanced EMI/EMC performance
  6. Low Power Consumption < 0.5W
  7. Power Supply :+3.3V
  8. Compatible to SFP+
  9. Temperature Range: 0~ 70 ¡ãC
  10. RoHS Compatible

Applications

  1. High capacity I/O in Storage Area Networks, Network Attached Storage, and Storage Servers
  2. Switched fabric I/O such as ultra high bandwidth switches and routers
  3. Data center cabling infrastructure
  4. High density connections between networking equipment

Product Description

The SFP+ active cable assemblies are high performance, cost effective I/O solutions for 10Gb Ethernet and 10G Fiber Channel applications. SFP+ copper modules allow hardware manufactures to achieve high port density, configurability and utilization at a very low cast and reduced power budget. The high speed cable assemblies meet and exceed Gigabit Ethernet and Fiber Channel industry standard requirements for performance and reliability.

Recommended Operating Conditions

Parameter

Symbol

Min

Typical

Max

Unit

Storage Ambient Temperature

 

-40

 

+85

¡ãC

Operating Case Temperature

Tc

0

 

+70

¡ãC

Power Supply Voltage

VCC3

3.14

3.3

3.47

V

Power Dissipation

PD

   

0.5

W

Systems

Performance

Media

Operating parameters

10.5Gbps line speed, full duplex

Bit error rate: better than 10E-12

Hot-pluggable, industry-standard Small Form-Factor

Pluggable(SFP+) copper cable, available max 10m

Supply voltage: 3.3V

Power consumption(per end): max 0.5W

Pin Descriptions

Pin

Logic

Symbol

Name/Description

Notes

1

 
VeeT
Transmitter Ground
 

2

LV-TTL-O

TX_Fault

N/A

1

3

LV-TTL-I

TX_DIS

Transmitter Disable

 

4

LV-TTL-I/O

SDA

Tow Wire Serial Data

 

5

LV-TTL-I

SCL

Tow Wire Serial Clock

 

6

 

MOD_DEF0

Module present, connect to VeeT

 

7

LV-TTL-I

RS0

N/A

1

8

LV-TTL-O

LOS

LOS of Signal

 

9

LV-TTL-I

RS1

N/A

1

10

 

VeeR

Reciever Ground

 

11

 

VeeR

Reciever Ground

 

12

CML-O

RD-

Reciever Data Inverted

 

13

CML-O

RD+

Reciever Data Non-Inverted

 

14

 

VeeR

Reciever Ground

 

15

 

VccR

Reciever Supply 3.3V

 

16

 

VccT

Transmitter Supply 3.3V

 

17

 

VeeT

Transmitter Ground

 

18

CML-I

TD+

Transmitter Data Non-Inverted

 

19

CML_I

TD-

Transmitter Data Inverted

 

20

 

VeeT

Transmitter Ground

 

1. Signals not supported in SFP+ Copper pulled-down   to VeeT with 30K ohms resistor

Ordering information

Part Number

Product Description

SFP-10GAC-5

SFP+ Direct Attach Active Cable(10GSFP+Cu), 5m, AWG:26, 0?C ~ +70?C

SFP-10GAC-7

SFP+ Direct Attach Active Cable(10GSFP+Cu), 7m, AWG:24, 0?C ~ +70?C

SFP-10GAC-10

SFP+ Direct Attach Active Cable(10GSFP+Cu), 10m, AWG:24, 0?C ~ +70?C

SFP-10GAC-12

SFP+ Direct Attach Active Cable(10GSFP+Cu), 12m, AWG:24, 0?C ~ +70?C

Note: You can be customized diameter and distance.

Important Notice

Performance figures, data and any illustrative material provided in this data sheet are typical and must be

specifically confirmed in writing by F-tone before they become applicable to any particular order or

contract. In accordance with the F-tone policy of continuous improvement specifications may change

without notice. The publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone or others. Further details are available from any F-tone sales representative.

 

È«¹ú²ú»¯¹âÄ£¿é CFP2¹âÄ£¿é JYSK¹âÏËÁ¬½ÓÆ÷ ˼¿Æ¹âÄ£¿é Marconi¹âÄ£¿é Test Equipment & Others ¹âÏË·¨À¼ÊÊÅäÆ÷
SFPÈ«¹ú²ú¹âÄ£¿é CFP4¹âÄ£¿é J599IIIµçÁ¬½ÓÆ÷ ˼¿ÆFE SFP ²©´ï¹âÄ£¿é ±£Æ«¹âÆ÷¼þ ¹âÏËÌøÏß&βÏË
1x9È«¹ú²ú¹âÄ£¿é CFP8 400Gbps S6¾ØÐÎÁ¬½ÓÆ÷ ˼¿ÆSFP+¹âÄ£¿é Íø¼þ¹âÄ£¿é In-line Depolarizer FTTAÀ­Ô¶»ùÕ¾¹âÏËÌøÏß
ÌØÖÖ¹âÄ£¿é CDFP 400Gbps S7¾ØÐÎÁ¬½ÓÆ÷ ˼¿ÆXFP¹âÄ£¿é Nortel¹âÄ£¿é In-line Polarizer MPO/MTP¸ßÃܶÈϵÁÐ
25G~400G¸ßËÙ¹âÄ£¿é MicroQSFP¹âÄ£¿é GYM¹âÏËÁ¬½ÓÆ÷ ˼¿ÆCFP¹âÄ£¿é Moxa¹âÄ£¿é IPBC/S ¾üÓÃÒ°Õ½·ÀË®¹âÏËÌøÏß
200km³¬³¤¾à¹âÄ£¿é DSFP¹âÄ£¿é J599III¹âÏËÁ¬½ÓÆ÷ ˼¿ÆQSFP-DD ¹âÄ£¿é º£¿µÍþÊÓHIKVISION¹âÄ£¿é PBC/S ÌØÖÖ¹âÏ˹âÀÂ
5GÒƶ¯Í¨ÐŹâÄ£¿é FT-61¹âÄ£¿é Ë®ÃܹâÀÂÁ¬½ÓÆ÷ ˼¿ÆQSFP+¹âÄ£¿é McAfee¹âÄ£¿é PM BPF ÌØÖÖÏßÀÂ×é¼þ
SFP¹âÄ£¿é OLT¹âÄ£¿é ¹âÏËÁ¬½ÓÆ÷ת½ÓÆ÷ ˼¿ÆGE SFP SMCÖÇ°î¹âÄ£¿é PM Circulator ͨÓùâÀ¹âÏËÌøÏß
1.25G SFP ONU¹âÄ£¿é FT-A4ϵÁÐÁ¬½ÓÆ÷ ˼¿ÆSFP OC3 °²»ª¸ßAvago¹âÄ£¿é PM Collimator MXC? ¶àо¹âÀÂ×é¼þ
CWDM SFP PLCC¹âÄ£¿é USB¹âÏËÑÓ³¤Ïß Ë¼¿ÆSFP OC12 °²»ª¸ßAvago 1x9¹âÄ£¿é PM Coupler PRIZM? LIGHTTURN?×é¼þ
DWDM SFP RJ¹âÄ£¿é HDMI ˼¿ÆSFP OC48 °²»ª¸ßAvago SFF¹âÄ£¿é PM CWDM ¹âÏË»úÏä
BIDI-SFP SFF¹âÄ£¿é ÌØÖÖµçÁ¬½ÓÆ÷ ˼¿ÆGBIC¹âÄ£¿é °²»ª¸ßAvago SFP¹âÄ£¿é PM DWDM SMA-ÌØÊâÏËоϵÁÐ
SGMII SFP SNAP12¹âÄ£¿é Ô²ÐÎÁ¬½ÓÆ÷ ˼¿ÆX2¹âÄ£¿é °²»ª¸ßAvago QSFP28 ¹âÄ£¿é PM Faraday mirror ÌØÊâ½ÓͷϵÁÐ
Video SFP¹âÄ£¿é USOT¹âÄ£¿é ¾ØÐεçÁ¬½ÓÆ÷ ˼¿ÆXENPAK¹âÄ£¿é °²»ª¸ßAvago QSFP+¹âÄ£¿é PM Fiber mirror îøװϵÁÐ
Copper SFP X2¹âÄ£¿é ÌØÖÖ¹âÏ˹âÀ »ªÈý¹âÄ£¿é °²»ª¸ßAvago SNAP12¹âÄ£¿é PM Filter Coupler ¹âñîºÏÆ÷Coupler
µÍ¹¦ºÄSFP Xenpak¹âÄ£¿é ÌØÖÖ¹âÏË »ªÈýSFP °²»ª¸ßAvago ÆäËû¹âÄ£¿é PM Fused Coupler ƤÏËÌøÏßϵÁÐ
SFP+¹âÄ£¿é ¹âµç±àÂëÆ÷Ä£¿é ¹âÏËÆ÷¼þ »ªÈýSFP+ °²»ª¸ß Embedded¹âÄ£¿é PM FWDM ´óоÊýϵÁÐ
CWDM SFP+ ¹âÄ£¿é²âÊÔ°å ÌØÖÖ¹âÀ¼°¹âÀÂ×é¼þ »ªÈýSFP28 ¹âÄ£¿é °²»ª¸ßFiber Optics¹âÄ£¿é PM Isolator »Ø·ÌøÏßϵÁÐ
DWDM SFP+ ¹âÄ£¿éÁý×Ó×ù×Ó ¹âź »ªÈýQSFP+¹âÄ£¿é Industrial Transmitters and Receivers PM Isolator WDM ±£Æ«¹âÏËϵÁÐ
BIDI SFP+ DAC ¸ßËÙÏßÀ ±ê×¼¹âñî »ªÈýQSFP28 ¹âÄ£¿é Optical Transceivers PM PLC ¹âͨÐÅ×é¼þ
Tunable SFP+ ¹âÏË»¬»·|¹âµç»¬»· SMA²âÊÔÏßÀ »ªÈý CFP¹âÄ£¿é ·Éͨ¹âÄ£¿é PM Tap Isolator ¹â¸ôÀëÆ÷isolator
16GFC SFP+ ¹âÀ³µ OSA »ªÈý CXP¹âÄ£¿é Finisar¹âÄ£¿é PM Tap Isolator WDM ÆäËü¹âÆ÷¼þ
25GE SFP+ ¾üÆ·¼¶DIN¹âÄ£¿é PON BOSA »ªÈý CX4¸ßËÙµçÀ ·ÆÄáÈøFinisar SFF¹âÄ£¿é PM VOA ¿Éµ÷Â˲¨Æ÷
32GFC SFP+ ËÜÁϹâÏËÄ£¿é Pigtailed PD »ªÈýXFP yellobrik SDI¹âÄ£¿é ÆäËü±£Æ«Æ÷¼þ ¿Éµ÷Ë¥¼õÆ÷
SFP28¹âÄ£¿é Ìæ»»°²»ª¸ß¹¤ÒµµçÁ¦¹âÄ£¿é RFoG BOSA »ªÈýGE SFP ÂÞ¿ËΤ¶ûAB¹âÄ£¿é ¹â·Ö·Æ÷ À­×¶ñîºÏÆ÷
SFP56¹âÄ£¿é ¼æÈݹú²ú»¯Ìæ»»°²»ª¸ß¹âñî TO-CAN »ªÈýFE SFP Â޽ܿµ¹âÄ£¿é FBTÀ­×¶·Ö·Æ÷ ÎÞÔ´¹âÆ÷¼þ
SFP-DD¹âÄ£¿é ÉäƵ¹âÄ£¿é ¹âÏËζȴ«¸ÐÆ÷ »ªÈýSFP STM-4 ÑлªAdvantech¹âÄ£¿é PLC ¹â·Ö·Æ÷ ·¨À­µÚÐýת¾µ
QSFP¹âÄ£¿é ΢ÐͶà·¹âÄ£¿é ¹âÏËÓ¦±ä´«¸ÐÆ÷ »ªÈýSFP STM-16 È«¹ú²ú»¯¹âÆ÷¼þ PLCƽÃ沨µ¼¹â·Ö·Æ÷ ²¨·Ö¸´ÓÃÆ÷
QSFP+ ¹âÄ£¿é ÌØÖÖ¹âÄ£¿é ¹âÏ˼ÓËٶȴ«¸ÐÆ÷ »ªÈýGBIC¹âÄ£¿é FT-XSϵÁР¹ú²ú»¯°ëµ¼Ìå¹â·Å´óÆ÷ ¹â¿ª¹Ø AWG DWDM²¨·Ö¸´ÓÃÆ÷
QSFP28¹âÄ£¿é HPC²¢ÐйâÄ£¿é ¹âÏßѹÁ¦´«¸ÐÆ÷ »ªÈýBIDI¹âÄ£¿é ¹âÏËÕóÁÐϵÁР̽²âÆ÷ Fused WDM²¨·Ö¸´ÓÃÆ÷
QSFP56¹âÄ£¿é LC-RJ³¬Ð¡Ð͵¥Â·¹âÄ£¿é ¹âÏËλÒÆ´«¸ÐÆ÷ »ªÈýXENPAK¹âÄ£¿é ¸ßËÙÄ£¿é΢Á¬½Ó ¹â¹¦ÂÊ¼Æ FWDM²¨·Ö¸´ÓÃÆ÷
QSFP112 400G¹âÄ£¿é LCC48¹âÄ£¿é ¹âÏËÓ¦Á¦´«¸ÐÆ÷ »ªÈýEPON OLT SFP Ïà¸ÉͨѶ¹âÁ¬½Ó È«¹âÏËÏàλÀ­ÉìÆ÷ Mini΢ÐÍ´Ö²¨·Ö¸´ÓÃÆ÷
QSFP224¹âÄ£¿é LC³¬¶ÌÐ͹âÄ£¿é ¹âÏË´«¸ÐÆÊÎöÒÇ Öк½¹âµç¹âÄ£¿é ¹è¹â×ÓÆ÷¼þ¹âÁ´½Ó ¹âÏË×¼Ö±Æ÷ ¹â·Ö²å¸´ÓÃÆ÷
QSFP-DD¹âÄ£¿é SNAP12¹âÄ£¿é ¹âÏËÂþÑÜʽ²âÎÂÖ÷»ú ÖÐÐ˹âÄ£¿é Bio-Medical Equipment ¹âË¥¼õÆ÷ϵÁÐ ÆäËüÖÖÀನ·Ö¸´ÓÃÆ÷²úƷϵÁÐ
QSFP-DD800¹âÄ£¿é ΢Ð͹âÄ£¿é ¹âÏ˲¼ÀïÔ¨ÐźŽâµ÷ÒÇ Èñ½Ý¹âÄ£¿é Components for Fiber Laser ¹âÆ«Õñ¿ØÖÆÆ÷ Ãܼ¯²¨·Ö¸´ÓÃÆ÷
OSFP 400Gbps ΢ÐͿɲå°ÎBGA¹âÄ£¿é ÂþÑÜʽ¹âÏËÉùÕñÐźŽâµ÷ÒÇ »ÝÆÕ¹âÄ£¿é Components for Fiber sensing ¹âÔ´ ´Ö²¨·Ö¸´ÓÃÆ÷
OSFP 800G¹âÄ£¿é ±íÌùʽµ¥Â·¹âÄ£¿é Camera Link ÉñÖÝÊýÂë¹âÄ£¿é Components for Optical Network ¹â»·ÐÐÆ÷Circulator WDMÄ£¿é
OSFP 1.6T¹âÄ£¿é ÌØÖÖ¹âÏËÁ¬½ÓÆ÷ ¹âÄ£¿é֪ʶ Juniper¹âÄ£¿é EDFA¹âÏË·Å´óÆ÷ ¹âÏËÑÓ³ÙÏß Â˲¨Æ÷
HSFP 1.6T~12.8T¹âÄ£¿é J599¹âÏ˲åÍ·²å×ù »ªÎª¹âÄ£¿é Extreme¹âÄ£¿é ¹âÏË´«¸ÐÆ÷ É«É¢Å⳥ģ¿é µûÐμ¤¹âÆ÷
XFP¹âÄ£¿é ODC¹âÏËÁ¬½ÓÆ÷ϵÁÐ »ªÎªGE SFP Brocade¹âÄ£¿é High power Component ¹âÏË·Å´óÆ÷ ¹âñîºÏÆ÷&·Ö·Æ÷
CWDM XFP ÆäËûÌØÖÖ¹âÏËÁ¬½ÓÆ÷ »ªÎªQSFP+¹âÄ£¿é D-Link¹âÄ£¿é HP In-line Polarizer ÎÞÔ´´«Êäת»»Æ÷ ¹âÏË»·ÐÎÆ÷&·¨À­µÚÐýת¾µ
DWDM XFP Ò°Õ½¹âÏËÁ¬½ÓÆ÷ »ªÎªSFP+ ºÕ˼Âü¹âÄ£¿é HP Isolator ¹âÏ˼¤¹âÆ÷ ¹âÏ˸ôÀëÆ÷&²¨·Ö¸´ÓÃÆ÷
BIDI XFP ÌØÖÖ¹âµçÁ¬½ÓÆ÷ »ªÎªQSFP28 °¢¶û¿¨ÌØÀÊѶ¹âÄ£¿é HP PBC/S ¹âµ÷ÖÆÆ÷ ¹âÏË·ÖÊøÆ÷&ºÏÊøÆ÷£¨PBS/PBC£©
1x9¹âÄ£¿é J599IIIÆéá«Æµ»ì×°Á¬½ÓÆ÷ »ªÎªFE SFP Allied Telesis¹âÄ£¿é Pump Combiner ¹âµç̽²âÆ÷ ¹âÏ˹âÕ¤
CSFP¹âÄ£¿é NGC¹âÏËÁ¬½ÓÆ÷ »ªÎªXFP Foundry¹âÄ£¿é HP Circulator ¹âÏËÆ«Õñ ¸ßËÙÏßÀÂ
CSFP+10G¹âÄ£¿é J599A6¹âÏËÁ¬½ÓÆ÷ »ªÎªSFP OC12 Force10¹âÄ£¿é Pump laser protector ¹âÏËÂ˲¨Æ÷
CXP¹âÄ£¿é GYMB¹âÏËÁ¬½ÓÆ÷ »ªÎªGBIC¹âÄ£¿é Blade¹âÄ£¿é Hybrid for EDFA ͬÖἤ¹âÆ÷
CFP¹âÄ£¿é J599III¹âµçÁ¬½ÓÆ÷ »ªÎªSFP STM16 Linksys¹âÄ£¿é Test Equipment & Others ͬÖáµçÀÂ

028-85255257 | sales@f-tone.com

±ê׼ЭÒé¹âÄ£¿é²úÆ·

¼æÈÝЭÒé¹âÄ£¿é

ÆäËüÖÖÀà¹âÆ÷¼þ

¼¼ÊõÖ§³Ö

ÍøÕ¾µØͼ
ÓÑÇéÁ´½Ó£º×ðÁú¿­Ê±  À­Ë¹Î¬¼Ó˹9888  »ªÌå»áhth  ×ðÁú¿­Ê±ÈËÉú¾ÍÊDz«  ×ðÁú¿­Ê±ÈËÉú¾ÍÊDz«  pgÃâ·ÑÓÎÏ·ÊÔÍæÍøÒ³°æ  ÃÀ¸ß÷¹ÙÍø  °ÙÀÖ²©  mg²»ÐàÇéÔµ  ÌÚ²©»á¹ÙÍø  Áú8¹ú¼Ê  Ð±¦ggÒ»¼üµÇ¼  pgµç×Ó  Â齫ºúÁËpg  ×ðÁú¿­Ê±ÈËÉú¾ÍÊDz«