´ó±¦ÓéÀÖ

±ê×¼¹âÄ£¿é

DWDM XFP

DWDM XFP

DWDM XFP ¹âÄ£¿é

DWDM XFP¹âÄ£¿é¾ÍÊÇËùνÃܼ¯²¨·Ö¸´Óã¨Dense Wavelength Division Multiplexing£©XFP·â×°µÄ¹âÄ£¿é£»

ËùνÃܼ¯²¨·Ö¸´Óã¨Dense Wavelength Division Multiplexing£©¼¼Êõ£¬Ö¸µÄÊÇÒ»ÖÖ¹âÏËÊý¾Ý´«Êä¼¼Êõ£¬ÕâÒ»¼¼ÊõÀûÓü¤¹âµÄ²¨³¤Æ¾¾Ý±ÈÌØλ²¢Ðд«Êä»òÕß×Ö·û´®Ðд«Êä·½·¨ÔÚ¹âÏËÄÚ´«ËÍÊý¾Ý ¡£DWDM ¹âÄ£¿éÊÇÕë¶ÔÃܼ¯²¨·Ö¸´ÓõĹâÄ£¿é,ËüÓÐ44¸ö³£ÓÃͨµÀ¿ÉÒÔÑ¡Ôñ
XFPµÄËÙÂÊÊÇ10G£¬²¢ÇÒÊÇ´®ÐйâÊÕ·¢Ä£¿éµÄÒ»ÖÖ±ê×¼»¯·â×° ¡£ËüÍêÈ«ÇкÏÒÔϱê×¼£º10G¹âÏËͨµÀ¡¢10GÒÔÌ«Íø¡¢SONET/OC-192ºÍSDH/STM-64 ¡£XFP¹âÄ£¿éÖ÷ÒªÓÃÓÚÊý¾ÝͨѶºÍµçÐÅ´«ÊäÍøµÄ¹âÏË´«ÊäXFPÄ£¿éÊÇÒ»ÖÖ¿ÉÈȲå°ÎµÄ¡¢Õ¼µç·°åÃæ»ýºÜСµÄ¡¢´®ÐУ­´®ÐйâÊÕ·¢Æ÷£¬¿ÉÒÔÖ§³ÖSONET OC©\192¡¢10 Gbps ÒÔÌ«Íø¡¢10 Gbps ¹âÏËͨµÀºÍG.709Á´Â· ¡£XFPÊÇ´®ÐÐ10G¹âÊÕ·¢Ä£¿éµÄÒ»ÖÖ±ê×¼»¯·â×° ¡£ËüÓëЭÒéÎ޹ز¢ÇÒÍêÈ«ÇкÏÒÔϱê×¼£º10GÒÔÌ«Íø¡¢10G¹âÏËͨµÀ¡¢SONET/OC-192ºÍSDH/STM-64 ¡£XFP¹âÊÕ·¢Ä£¿éÓÃÓÚÊý¾ÝͨѶºÍµçÐÅ´«ÊäÍøµÄ¹âÏËÁ¬½Ó²¢ÇÒÆäÓŵãÔÚÓÚÓµÓбÈÆäËû10G¹âת·¢Æ÷£¨ÈçXENPAK¡¢X2£©¸üСµÄ¹Ü½Å ¡£Ö÷°åµÄµç½Ó¿ÚÊDZê×¼»¯µÄ³ÆΪXFIµÄ10G´®ÐнӿÚ ¡£

DWDM XFP¹âÄ£¿éÖÐÐIJ¨³¤¹²44¸ö²¨¶Î£¬ÔÚ 9/125um SMF±ê×¼µ¥Ä£¹âÏËÉÏ´«Êä¾àÀë¿É´ï40KM~120KM ¡£ÊÂÇéζȹæÄ£ÔÚStandard :  0 to +70¡ãC / Industrial : -40 to +85¡ãC  Ö® ¼ä£¬´øÊý×ÖÕï¶Ï¼à¿Ø¹¦Ð§ ¡£¾ßÓиßÃܶȵ͹¦ºÄµÄÌص㣬²úÆ·ÓµÓм«¸ßÐÔ¼Û±È ¡£²úÆ·¼æÈÝCISCO£¬HP£¬»ªÎª£¬²© ¿Æ£¬QLogic£¬H3C£¬3COM£¬JUNIPER£¬EXTREMEµÈº£ÄÚÍâÖ÷Á÷Ïà¹ØÉ豸 ¡£²úƷͨ¹ýCE£¬FCC£¬RoHSµÈ¹ú¼ÊÈÏÖ¤ ¡£F-toneÉú ²úµÄDWDM XFPϵÁйâÄ£¿éÖ§³Ö´«Êä¾àÀë40KM¡«120KM ¡£

ÏàÓ¦µÄ´«Ê䲨³¤ÓÐC-band ¦Ëc Wavelength Guide

ITU Channel       Product Code Frequency(THz) Wavelength ITU Channel Product Code Frequency(THz) Wavelength
17 191.7 1563.86 40 194 1545.32
18 191.8 1563.05 41 194.1 1544.53
19 191.9 1562.23 42 194.2 1543.73
20 192 1561.42 43 194.3 1542.94
21 192.1 1560.61 44 194.4 1542.14
22 192.2 1559.79 45 194.5 1541.35
23 192.3 1558.98 46 194.6 1540.56
24 192.4 1558.17 47 194.7 1539.77
25 192.5 1557.36 48 194.8 1538.98
26 192.6 1556.55 49 194.9 1538.19
27 192.7 1555.75 50 195 1537.4
28 192.8 1554.94 51 195.1 1536.61
29 192.9 1554.13 52 195.2 1535.82
30 193 1553.33 53 195.3 1535.04
31 193.1 1552.52 54 195.4 1534.25
32 193.2 1551.72 55 195.5 1533.47
33 193.3 1550.92 56 195.6 1532.68
34 193.4 1550.12 57 195.7 1531.9
35 193.5 1549.32 58 195.8 1531.12
36 193.6 1548.51 59 195.9 1530.33
37 193.7 1547.72 60 196 1529.55
38 193.8 1546.92 61 196.1 1528.77
39 193.9 1546.12      
  • 50GHz DWDM XFP 40KM Transceiver
  • 50GHz DWDM XFP 80KM Transceiver
  • 50GHz DWDM XFP 120KM Transceiver
  • 100GHz DWDM XFP 40KM Transceiver
  • 100GHz DWDM XFP 80KM Transceiver
  • 100GHz DWDM XFP 120KM Transceiver
  • 200GHz DWDM XFP 40KM Transceiver
  • 200GHz DWDM XFP 80KM Transceiver
  • 200GHz DWDM XFP 120KM Transceiver

 

 

DWDM XFP

DWDM XFP 120KM

DWDM XFP 120KM

  • Wavelength selectable to C-band ITU-T grid wavelengths            
  • Suitable for use in 100GHz channel spacing DWDM systems
  • XFP MSA Rev 4.5 Compliant
  • Data rate from 9.95Gbps to 11.3Gbps
  • Cooled EML and APD receiver
  • link length up to 120km (with amplifier)
  • Low Power Dissipation 3.5W Maximum
  • XFI and lineside loopback Mode Supported
  • Operating Case Temperature 0¡ãC to 70¡ãC(Standard), -40¡ãC to 85¡ãC
  • Diagnostic Performance Monitoring of module temperature,Supply Voltages, laser bias current, transmit optical power, and receive optical power
  • RoHS compliant (lead free)

DWDM XFP 40KM

DWDM XFP 40KM

  1. Wavelength selectable to C-band ITU-T grid
  2. Suitable for use in 100GHz channel spacing DWDM systems
  3. XFP MSA Compliant
  4. data rate from 9.95 Gbps to 11.3Gbps
  5. No Reference Clock required
  6. Cold Start up Wavelength Compliance
  7. DWDM-rated EML transmitter and PIN receiver
  8. link length up to 40km
  9. Low Power Dissipation 3.5W Maximum
  10. Operating Case Temperature 0¡ãC to 70¡ãC(Standard), -40¡ãC to 85¡ãC (Industrial)
  11. Diagnostic Performance Monitoring of module temperature, supply Voltages, laser bias current, transmit optical power, receive optical power
  12. RoHS compliant and lead free

DWDM XFP 80KM

DWDM XFP 80KM

  1. Wavelength selectable to C-band ITU-T grid
  2. Suitable for use in 100GHz channel spacing DWDM systems
  3. XFP MSA Compliant
  4. data rate from 9.95 Gbps to 11.1Gbps
  5. No Reference Clock required
  6. Cold Start up Wavelength Compliance
  7. DWDM-rated EML transmitter and APD receiver
  8. link length up to 80km
  9. Low Power Dissipation 3.5W Maximum
  10. Operating Case Temperature 0¡ãC to 70¡ãC(Standard), -40¡ãC to 85¡ãC (Industrial)
  11. Diagnostic Performance Monitoring of module temperature, supply Voltages, laser bias current, transmit optical power, receive optical power
  12. RoHS compliant and lead free

DWDM XFPÍòÕ×¹âÄ£¿é

DWDM XFPÍòÕ×¹âÄ£¿é

DWDM XFPÍòÕ×¹âÄ£¿é

Éè¼ÆÓÃÓÚ10GÒÔÌ«Íø,OTN OTU2e,10G¹âÏËͨµÀ,SONET OC-192ºÍSDH STM-64ͨ¹ýË«¹¤µ¥Ä£¹âÏËÁ´Â·,ʹÓÃ100GHz¼ä¸ôµÄC²¨¶ÎDWDM²¨³¤ ¡£

DWDM XFPÍòÕ×¹âÄ£¿é£¨20km£©

DWDM XFPÍòÕ×¹âÄ£¿é£¨20km£©

DWDM XFPÍòÕ×¹âÄ£¿é£¨20km£©

´ó±¦ÓéÀÖ10G DWDM XFP 20km¹¤Òµ¹âÏËÊÕ·¢Æ÷רΪ˫¹¤µ¥Ä£¹âÏËÉϵÄÍòÕ×ÒÔÌ«Íø,10G¹âÏËͨµÀ,SONET OC-192,SDH STM-64ºÍOTN OTU2eÁ´Â·¶øÉè¼Æ ¡£¸ÃÄ£¿éÊÂÇéÔÚC²¨¶ÎC17-C61µÄ²¨³¤¹æÄ£ÄÚ,¼ä¸ôΪ100GHz,´«Êä¾àÀë¿É´ï20km ¡£

DWDM XFPÍòÕ×¹âÄ£¿é£¨40km£©

DWDM XFPÍòÕ×¹âÄ£¿é£¨40km£©

DWDM XFPÍòÕ×¹âÄ£¿é£¨40km£©

´ó±¦ÓéÀÖ10G DWDM XFP 20km¹¤Òµ¹âÏËÊÕ·¢Æ÷רΪ˫¹¤µ¥Ä£¹âÏËÉϵÄÍòÕ×ÒÔÌ«Íø,10G¹âÏËͨµÀ,SONET OC-192,SDH STM-64ºÍOTN OTU2eÁ´Â·¶øÉè¼Æ ¡£¸ÃÄ£¿éÊÂÇéÔÚC²¨¶ÎC17-C61µÄ²¨³¤¹æÄ£ÄÚ,¼ä¸ôΪ100GHz,´«Êä¾àÀë¿É´ï40km ¡£

DWDM XFPÍòÕ×¹âÄ£¿é£¨70km£©

DWDM XFPÍòÕ×¹âÄ£¿é£¨70km£©

DWDM XFPÍòÕ×¹âÄ£¿é£¨70km£©

´ó±¦ÓéÀÖ10G DWDM XFP 20km¹¤Òµ¹âÏËÊÕ·¢Æ÷רΪ˫¹¤µ¥Ä£¹âÏËÉϵÄÍòÕ×ÒÔÌ«Íø,10G¹âÏËͨµÀ,SONET OC-192,SDH STM-64ºÍOTN OTU2eÁ´Â·¶øÉè¼Æ ¡£¸ÃÄ£¿éÊÂÇéÔÚC²¨¶ÎC17-C61µÄ²¨³¤¹æÄ£ÄÚ,¼ä¸ôΪ100GHz,´«Êä¾àÀë¿É´ï70km ¡£

Tunable DWDM XFP

Tunable DWDM XFP transceiver

Tunable XFP transceiver ÖÐÎÄÃû³Æ Ϊ ¿Éµ÷г XFP ¹âÄ£¿é, ÊÇÒ»ÖÖ¿ÉÈȲå°ÎµÄ£¬¶ÀÁ¢ÓÚͨÐÅЭÒéµÄ¹âѧÊÕ·¢Æ÷£¬ÆäÌصãÊÇÊÂÇ鲨³¤¿ÉÒÔµ÷гµÄ£¬ÓÃÓÚ10G bpsµÄSONET/SDH£¬¹âÏËͨµÀ£¬gigabit Ethernet£¬10 gigabit EthernetºÍÆäËûÓ¦ÓÃÖÐ ¡£

F-tone 10G XFP TunableʵÏÖÁ¿²ú ¡£×÷Ϊ10G²úÆ·ÏßµÄÖØÒª×é³É²¿·Ö£¬DWDM¹âÊÕ·¢Ä£¿é±»¹ã·ºÓ¦ÓÃÓÚÖ÷¸ÉÍøºÍ³ÇÓòÍø´«Ê䣬Ïà¹ØÓÚTDM¹âÊÕ·¢Ä£¿é£¬DWDMÄÜ×î´ó Ï޶ȵÄÀûÓùâÏË×ÊÔ´£¬ÒÔ100GHz»ò50GHz²¨³¤¼ä¸ô£¬ÁýÕÖ40kmµ½120km£¬ÊµÏÖ¶à´ï100¸öͨµÀµÄÐźŴ«Êä ¡£

XFP DWDM

XFP DWDM Transceivers

F-tone DWDM XFP transceivers are available in channels defined in the ITU Grid (100 GHz spacing), from Channel 19 to Channel 61, or ITU Grid (50Ghz spacing), from channel 200 to 592ch. F-tone currently offers DWDM XFP optics for 10G networking at ranges between 40km, 80km. DWDM XFP 120km is under development now.

È«¹ú²ú»¯¹âÄ£¿é CFP2¹âÄ£¿é JYSK¹âÏËÁ¬½ÓÆ÷ ˼¿Æ¹âÄ£¿é Marconi¹âÄ£¿é Test Equipment & Others ¹âÏË·¨À¼ÊÊÅäÆ÷
SFPÈ«¹ú²ú¹âÄ£¿é CFP4¹âÄ£¿é J599IIIµçÁ¬½ÓÆ÷ ˼¿ÆFE SFP ²©´ï¹âÄ£¿é ±£Æ«¹âÆ÷¼þ ¹âÏËÌøÏß&βÏË
1x9È«¹ú²ú¹âÄ£¿é CFP8 400Gbps S6¾ØÐÎÁ¬½ÓÆ÷ ˼¿ÆSFP+¹âÄ£¿é Íø¼þ¹âÄ£¿é In-line Depolarizer FTTAÀ­Ô¶»ùÕ¾¹âÏËÌøÏß
ÌØÖÖ¹âÄ£¿é CDFP 400Gbps S7¾ØÐÎÁ¬½ÓÆ÷ ˼¿ÆXFP¹âÄ£¿é Nortel¹âÄ£¿é In-line Polarizer MPO/MTP¸ßÃܶÈϵÁÐ
25G~400G¸ßËÙ¹âÄ£¿é MicroQSFP¹âÄ£¿é GYM¹âÏËÁ¬½ÓÆ÷ ˼¿ÆCFP¹âÄ£¿é Moxa¹âÄ£¿é IPBC/S ¾üÓÃÒ°Õ½·ÀË®¹âÏËÌøÏß
200km³¬³¤¾à¹âÄ£¿é DSFP¹âÄ£¿é J599III¹âÏËÁ¬½ÓÆ÷ ˼¿ÆQSFP-DD ¹âÄ£¿é º£¿µÍþÊÓHIKVISION¹âÄ£¿é PBC/S ÌØÖÖ¹âÏ˹âÀÂ
5GÒƶ¯Í¨ÐŹâÄ£¿é FT-61¹âÄ£¿é Ë®ÃܹâÀÂÁ¬½ÓÆ÷ ˼¿ÆQSFP+¹âÄ£¿é McAfee¹âÄ£¿é PM BPF ÌØÖÖÏßÀÂ×é¼þ
SFP¹âÄ£¿é OLT¹âÄ£¿é ¹âÏËÁ¬½ÓÆ÷ת½ÓÆ÷ ˼¿ÆGE SFP SMCÖÇ°î¹âÄ£¿é PM Circulator ͨÓùâÀ¹âÏËÌøÏß
1.25G SFP ONU¹âÄ£¿é FT-A4ϵÁÐÁ¬½ÓÆ÷ ˼¿ÆSFP OC3 °²»ª¸ßAvago¹âÄ£¿é PM Collimator MXC? ¶àо¹âÀÂ×é¼þ
CWDM SFP PLCC¹âÄ£¿é USB¹âÏËÑÓ³¤Ïß Ë¼¿ÆSFP OC12 °²»ª¸ßAvago 1x9¹âÄ£¿é PM Coupler PRIZM? LIGHTTURN?×é¼þ
DWDM SFP RJ¹âÄ£¿é HDMI ˼¿ÆSFP OC48 °²»ª¸ßAvago SFF¹âÄ£¿é PM CWDM ¹âÏË»úÏä
BIDI-SFP SFF¹âÄ£¿é ÌØÖÖµçÁ¬½ÓÆ÷ ˼¿ÆGBIC¹âÄ£¿é °²»ª¸ßAvago SFP¹âÄ£¿é PM DWDM SMA-ÌØÊâÏËоϵÁÐ
SGMII SFP SNAP12¹âÄ£¿é Ô²ÐÎÁ¬½ÓÆ÷ ˼¿ÆX2¹âÄ£¿é °²»ª¸ßAvago QSFP28 ¹âÄ£¿é PM Faraday mirror ÌØÊâ½ÓͷϵÁÐ
Video SFP¹âÄ£¿é USOT¹âÄ£¿é ¾ØÐεçÁ¬½ÓÆ÷ ˼¿ÆXENPAK¹âÄ£¿é °²»ª¸ßAvago QSFP+¹âÄ£¿é PM Fiber mirror îøװϵÁÐ
Copper SFP X2¹âÄ£¿é ÌØÖÖ¹âÏ˹âÀ »ªÈý¹âÄ£¿é °²»ª¸ßAvago SNAP12¹âÄ£¿é PM Filter Coupler ¹âñîºÏÆ÷Coupler
µÍ¹¦ºÄSFP Xenpak¹âÄ£¿é ÌØÖÖ¹âÏË »ªÈýSFP °²»ª¸ßAvago ÆäËû¹âÄ£¿é PM Fused Coupler ƤÏËÌøÏßϵÁÐ
SFP+¹âÄ£¿é ¹âµç±àÂëÆ÷Ä£¿é ¹âÏËÆ÷¼þ »ªÈýSFP+ °²»ª¸ß Embedded¹âÄ£¿é PM FWDM ´óоÊýϵÁÐ
CWDM SFP+ ¹âÄ£¿é²âÊÔ°å ÌØÖÖ¹âÀ¼°¹âÀÂ×é¼þ »ªÈýSFP28 ¹âÄ£¿é °²»ª¸ßFiber Optics¹âÄ£¿é PM Isolator »Ø·ÌøÏßϵÁÐ
DWDM SFP+ ¹âÄ£¿éÁý×Ó×ù×Ó ¹âź »ªÈýQSFP+¹âÄ£¿é Industrial Transmitters and Receivers PM Isolator WDM ±£Æ«¹âÏËϵÁÐ
BIDI SFP+ DAC ¸ßËÙÏßÀ ±ê×¼¹âñî »ªÈýQSFP28 ¹âÄ£¿é Optical Transceivers PM PLC ¹âͨÐÅ×é¼þ
Tunable SFP+ ¹âÏË»¬»·|¹âµç»¬»· SMA²âÊÔÏßÀ »ªÈý CFP¹âÄ£¿é ·Éͨ¹âÄ£¿é PM Tap Isolator ¹â¸ôÀëÆ÷isolator
16GFC SFP+ ¹âÀ³µ OSA »ªÈý CXP¹âÄ£¿é Finisar¹âÄ£¿é PM Tap Isolator WDM ÆäËü¹âÆ÷¼þ
25GE SFP+ ¾üÆ·¼¶DIN¹âÄ£¿é PON BOSA »ªÈý CX4¸ßËÙµçÀ ·ÆÄáÈøFinisar SFF¹âÄ£¿é PM VOA ¿Éµ÷Â˲¨Æ÷
32GFC SFP+ ËÜÁϹâÏËÄ£¿é Pigtailed PD »ªÈýXFP yellobrik SDI¹âÄ£¿é ÆäËü±£Æ«Æ÷¼þ ¿Éµ÷Ë¥¼õÆ÷
SFP28¹âÄ£¿é Ìæ»»°²»ª¸ß¹¤ÒµµçÁ¦¹âÄ£¿é RFoG BOSA »ªÈýGE SFP ÂÞ¿ËΤ¶ûAB¹âÄ£¿é ¹â·Ö·Æ÷ À­×¶ñîºÏÆ÷
SFP56¹âÄ£¿é ¼æÈݹú²ú»¯Ìæ»»°²»ª¸ß¹âñî TO-CAN »ªÈýFE SFP Â޽ܿµ¹âÄ£¿é FBTÀ­×¶·Ö·Æ÷ ÎÞÔ´¹âÆ÷¼þ
SFP-DD¹âÄ£¿é ÉäƵ¹âÄ£¿é ¹âÏËζȴ«¸ÐÆ÷ »ªÈýSFP STM-4 ÑлªAdvantech¹âÄ£¿é PLC ¹â·Ö·Æ÷ ·¨À­µÚÐýת¾µ
QSFP¹âÄ£¿é ΢ÐͶà·¹âÄ£¿é ¹âÏËÓ¦±ä´«¸ÐÆ÷ »ªÈýSFP STM-16 È«¹ú²ú»¯¹âÆ÷¼þ PLCƽÃ沨µ¼¹â·Ö·Æ÷ ²¨·Ö¸´ÓÃÆ÷
QSFP+ ¹âÄ£¿é ÌØÖÖ¹âÄ£¿é ¹âÏ˼ÓËٶȴ«¸ÐÆ÷ »ªÈýGBIC¹âÄ£¿é FT-XSϵÁР¹ú²ú»¯°ëµ¼Ìå¹â·Å´óÆ÷ ¹â¿ª¹Ø AWG DWDM²¨·Ö¸´ÓÃÆ÷
QSFP28¹âÄ£¿é HPC²¢ÐйâÄ£¿é ¹âÏßѹÁ¦´«¸ÐÆ÷ »ªÈýBIDI¹âÄ£¿é ¹âÏËÕóÁÐϵÁР̽²âÆ÷ Fused WDM²¨·Ö¸´ÓÃÆ÷
QSFP56¹âÄ£¿é LC-RJ³¬Ð¡Ð͵¥Â·¹âÄ£¿é ¹âÏËλÒÆ´«¸ÐÆ÷ »ªÈýXENPAK¹âÄ£¿é ¸ßËÙÄ£¿é΢Á¬½Ó ¹â¹¦ÂÊ¼Æ FWDM²¨·Ö¸´ÓÃÆ÷
QSFP112 400G¹âÄ£¿é LCC48¹âÄ£¿é ¹âÏËÓ¦Á¦´«¸ÐÆ÷ »ªÈýEPON OLT SFP Ïà¸ÉͨѶ¹âÁ¬½Ó È«¹âÏËÏàλÀ­ÉìÆ÷ Mini΢ÐÍ´Ö²¨·Ö¸´ÓÃÆ÷
QSFP224¹âÄ£¿é LC³¬¶ÌÐ͹âÄ£¿é ¹âÏË´«¸ÐÆÊÎöÒÇ Öк½¹âµç¹âÄ£¿é ¹è¹â×ÓÆ÷¼þ¹âÁ´½Ó ¹âÏË×¼Ö±Æ÷ ¹â·Ö²å¸´ÓÃÆ÷
QSFP-DD¹âÄ£¿é SNAP12¹âÄ£¿é ¹âÏËÂþÑÜʽ²âÎÂÖ÷»ú ÖÐÐ˹âÄ£¿é Bio-Medical Equipment ¹âË¥¼õÆ÷ϵÁÐ ÆäËüÖÖÀನ·Ö¸´ÓÃÆ÷²úƷϵÁÐ
QSFP-DD800¹âÄ£¿é ΢Ð͹âÄ£¿é ¹âÏ˲¼ÀïÔ¨ÐźŽâµ÷ÒÇ Èñ½Ý¹âÄ£¿é Components for Fiber Laser ¹âÆ«Õñ¿ØÖÆÆ÷ Ãܼ¯²¨·Ö¸´ÓÃÆ÷
OSFP 400Gbps ΢ÐͿɲå°ÎBGA¹âÄ£¿é ÂþÑÜʽ¹âÏËÉùÕñÐźŽâµ÷ÒÇ »ÝÆÕ¹âÄ£¿é Components for Fiber sensing ¹âÔ´ ´Ö²¨·Ö¸´ÓÃÆ÷
OSFP 800G¹âÄ£¿é ±íÌùʽµ¥Â·¹âÄ£¿é Camera Link ÉñÖÝÊýÂë¹âÄ£¿é Components for Optical Network ¹â»·ÐÐÆ÷Circulator WDMÄ£¿é
OSFP 1.6T¹âÄ£¿é ÌØÖÖ¹âÏËÁ¬½ÓÆ÷ ¹âÄ£¿é֪ʶ Juniper¹âÄ£¿é EDFA¹âÏË·Å´óÆ÷ ¹âÏËÑÓ³ÙÏß Â˲¨Æ÷
HSFP 1.6T~12.8T¹âÄ£¿é J599¹âÏ˲åÍ·²å×ù »ªÎª¹âÄ£¿é Extreme¹âÄ£¿é ¹âÏË´«¸ÐÆ÷ É«É¢Å⳥ģ¿é µûÐμ¤¹âÆ÷
XFP¹âÄ£¿é ODC¹âÏËÁ¬½ÓÆ÷ϵÁÐ »ªÎªGE SFP Brocade¹âÄ£¿é High power Component ¹âÏË·Å´óÆ÷ ¹âñîºÏÆ÷&·Ö·Æ÷
CWDM XFP ÆäËûÌØÖÖ¹âÏËÁ¬½ÓÆ÷ »ªÎªQSFP+¹âÄ£¿é D-Link¹âÄ£¿é HP In-line Polarizer ÎÞÔ´´«Êäת»»Æ÷ ¹âÏË»·ÐÎÆ÷&·¨À­µÚÐýת¾µ
DWDM XFP Ò°Õ½¹âÏËÁ¬½ÓÆ÷ »ªÎªSFP+ ºÕ˼Âü¹âÄ£¿é HP Isolator ¹âÏ˼¤¹âÆ÷ ¹âÏ˸ôÀëÆ÷&²¨·Ö¸´ÓÃÆ÷
BIDI XFP ÌØÖÖ¹âµçÁ¬½ÓÆ÷ »ªÎªQSFP28 °¢¶û¿¨ÌØÀÊѶ¹âÄ£¿é HP PBC/S ¹âµ÷ÖÆÆ÷ ¹âÏË·ÖÊøÆ÷&ºÏÊøÆ÷£¨PBS/PBC£©
1x9¹âÄ£¿é J599IIIÆéá«Æµ»ì×°Á¬½ÓÆ÷ »ªÎªFE SFP Allied Telesis¹âÄ£¿é Pump Combiner ¹âµç̽²âÆ÷ ¹âÏ˹âÕ¤
CSFP¹âÄ£¿é NGC¹âÏËÁ¬½ÓÆ÷ »ªÎªXFP Foundry¹âÄ£¿é HP Circulator ¹âÏËÆ«Õñ ¸ßËÙÏßÀÂ
CSFP+10G¹âÄ£¿é J599A6¹âÏËÁ¬½ÓÆ÷ »ªÎªSFP OC12 Force10¹âÄ£¿é Pump laser protector ¹âÏËÂ˲¨Æ÷
CXP¹âÄ£¿é GYMB¹âÏËÁ¬½ÓÆ÷ »ªÎªGBIC¹âÄ£¿é Blade¹âÄ£¿é Hybrid for EDFA ͬÖἤ¹âÆ÷
CFP¹âÄ£¿é J599III¹âµçÁ¬½ÓÆ÷ »ªÎªSFP STM16 Linksys¹âÄ£¿é Test Equipment & Others ͬÖáµçÀÂ

028-85255257 | sales@f-tone.com

±ê׼ЭÒé¹âÄ£¿é²úÆ·

¼æÈÝЭÒé¹âÄ£¿é

ÆäËüÖÖÀà¹âÆ÷¼þ

¼¼ÊõÖ§³Ö

ÍøÕ¾µØͼ
ÓÑÇéÁ´½Ó£ºÔƶ¥4008ÓÎÏ·µÇ¼  GA»Æ½ð¼×  »Ê¹Úhg8868ÀÏ°æ±¾  À×¾º¼¼¹ÙÍøÍøÕ¾  ×ðÁú¿­Ê±ÈËÉú¾ÍÊDz«  Öîºî¿ìѶ  Ôƶ¥¹ú¼Ê  ca88  ×ðÁú¿­Ê±ÈËÉú¾ÍÊDz«  Ã×ÀÖ  Å·²©abg  ´ó·¢welcomeµÇ¼  ×ðÁú¿­Ê±ÈËÉú¾ÍÊDz«  918²©ÌìÌà ¹Ú¾ü¹ú¼ÊÍø