SFF¹âÄ£¿é-2x5·â×° 622MbpsËÙÂÊ£º
0¡ãC to +70¡ãC
-40¡ãC to +85¡ãC for industry level
SFF¹âÄ£¿é-2x5·â×° 622MbpsËÙÂÊÏÈÐÍÊֲ᣺
Table 1: Order Information
Type |
Fiber Type |
Wavelength(nm) |
Fiber Length(Km) |
Temperature ranges |
Signal TX /Signal RX/Signal Detect |
FTAF-1306-20 |
SM |
1310nm |
20 |
0¡ãC to +70¡ãC |
TX:LVPECL/RX:LVPECL/SD:LVTTL |
FTAF-1306-40 |
SM |
1310nm |
40 |
0¡ãC to +70¡ãC |
TX:LVPECL/RX:LVPECL/SD:LVTTL |
FTAF-1306-60 |
SM |
1310nm |
60 |
0¡ãC to +70¡ãC |
TX:LVPECL/RX:LVPECL/SD:LVTTL |
FTAF-1506-20 |
SM |
1550nm |
20 |
0¡ãC to +70¡ãC |
TX:LVPECL/RX:LVPECL/SD:LVTTL |
FTAF-1506-40 |
SM |
1550nm |
40 |
0¡ãC to +70¡ãC |
TX:LVPECL/RX:LVPECL/SD:LVTTL |
FTAF-1506-60 |
SM |
1550nm |
60 |
0¡ãC to +70¡ãC |
TX:LVPECL/RX:LVPECL/SD:LVTTL |
FTAF-1506-80 |
SM |
1550nm |
80 |
0¡ãC to +70¡ãC |
TX:LVPECL/RX:LVPECL/SD:LVTTL |
FTAF-1506-H0 |
SM |
1550nm |
100 |
0¡ãC to +70¡ãC |
TX:LVPECL/RX:LVPECL/SD:LVTTL |
FTAF-1506-H2 |
SM |
1550nm |
120 |
0¡ãC to +70¡ãC |
TX:LVPECL/RX:LVPECL/SD:LVTTL |
Order Information for industry level
Type |
Fiber Type |
Wavelength(nm) |
Fiber Length(Km) |
Temperature ranges |
Signal TX /Signal RX/Signal Detect |
FTAF-1306-20I |
SM |
1310nm |
20 |
-40¡ãC to +85¡ãC |
TX:LVPECL/RX:LVPECL/SD:LVTTL |
FTAF-1306-40I |
SM |
1310nm |
40 |
-40¡ãC to +85¡ãC |
TX:LVPECL/RX:LVPECL/SD:LVTTL |
FTAF-1306-60I |
SM |
1310nm |
60 |
-40¡ãC to +85¡ãC |
TX:LVPECL/RX:LVPECL/SD:LVTTL |
FTAF-1506-20I |
SM |
1550nm |
20 |
-40¡ãC to +85¡ãC |
TX:LVPECL/RX:LVPECL/SD:LVTTL |
FTAF-1506-40I |
SM |
1550nm |
40 |
-40¡ãC to +85¡ãC |
TX:LVPECL/RX:LVPECL/SD:LVTTL |
FTAF-1506-60I |
SM |
1550nm |
60 |
-40¡ãC to +85¡ãC |
TX:LVPECL/RX:LVPECL/SD:LVTTL |
FTAF-1506-80I |
SM |
1550nm |
80 |
-40¡ãC to +85¡ãC |
TX:LVPECL/RX:LVPECL/SD:LVTTL |
FTAF-1506-H0I |
SM |
1550nm |
100 |
-40¡ãC to +85¡ãC |
TX:LVPECL/RX:LVPECL/SD:LVTTL |
FTAF-1506-H2I |
SM |
1550nm |
120 |
-40¡ãC to +85¡ãC |
TX:LVPECL/RX:LVPECL/SD:LVTTL |
SFF¹âÄ£¿é-2x5·â×° 622MbpsËÙÂÊ×¢ÒâÊÂÏ
Important Notice
Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.
The publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.