´ó±¦ÓéÀÖ

²¨·Ö¸´ÓÃÆ÷

±ê׼ЭÒé¹âÄ£¿é

¼æÈÝЭÒé¹âÄ£¿é

ÆäËüÖÖÀà¹âÆ÷¼þ

¼¼ÊõÖ§³Ö

Ultra Compact Cable-Type WDM (Mux + DeMux)

Ultra Compact Cable-Type WDM (Mux + DeMux)

0.0/5 rating (0 votes)

Description

´ó±¦ÓéÀÖרҵÑб¬·¢²ú:Ultra Compact Cable-Type WDM (Mux + DeMux), ÊÇÒ»¼ÒרҵµÄUltra Compact Cable-Type WDM (Mux + DeMux)³§¼Ò,¾ßÓÐÓÅÖʵÄUltra Compact Cable-Type WDM (Mux + DeMux)Æ·ÖÊ,ÓкܺõÄUltra Compact Cable-Type WDM (Mux + DeMux)¼Û¸ñ,Ultra Compact Cable-Type WDM (Mux + DeMux)º£Á¿½»¸¶¸ø¹ú·À¡¢¾ü¹¤¡¢º½¿Õ¡¢º½Ìì¡¢ÎäÆ÷¡¢½¢´¬¡¢À×´ï¡¢µç×Ó¡¢ºË¹¤Òµ¡¢¾üÊ¡¢µçÁ¦¡¢Ìú·¡¢Ò½ÁÆ¡¢½»Í¨¡¢Í¨ÐÅ¡¢µçÐÅ¡¢Õþ¸®¡¢¹ú·À¿Æ¼¼¹¤ÒµÏµÍ³ÄÚ´óרԺУ¼°¿ÆÑÐÔºËù

Parameter Specifications: CWDM Mux & DeMux in a single package

Parameters

Unit

2x4 Channels

(2 common ports)

1x8 Channels

(1 common port)

Insertion Loss

dB

≤1.2

≤1.7

Ripple

dB

≤0.5

Polarization Dependent Loss

dB

≤0.3

Dimension

mm

50x12x6.5

Choice of Center Wavelengths

nm

1271 - 1611

Channel Spacing

nm

20

Channel Passband

nm

λc ± 6.5£¨Min.£©

Isolation-Adjacent

dB

≥30

Isolation-Non-adjacent

dB

≥40

Return Loss

dB

≥45

Directivity  

dB

≥50

Notes: The above specs exclude connector loss, each pair of connectors add 0.2dB

Parameter Specifications: DWDM Mux & DeMux in a single package

Parameters

Unit

2x4 Channels

(2 common ports)

1x8 Channels

(1 common port)

Insertion Loss

dB

≤1.5

≤2.0

Ripple

dB

≤0.5

Polarization Dependent Loss

dB

≤0.3

Dimension

mm

60x14.4x6.5

Choice of Center Wavelengths

nm

ITU channels

Channel Spacing

nm

100G:0.8

200G:1.6

Channel Passband

nm

100G: λc ± 0.11£¨Min.£©

200G: λc ± 0.25£¨Min.£©

Isolation-Adjacent

dB

≥30

Isolation-Non-adjacent

dB

≥40

Return Loss

dB

≥45

Directivity  

dB

≥50

 

 

 

 

Important Notice

Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.

The publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.

Search