1270/1330nm TX / 1330/1270 nm RX
Features
Applications
Product description
The FTCS-BXX1X-40XX series single mode transceiver is small form factor pluggable module for duplex optical data communications such as 10GBASE-ER/LW defined by IEEE 802.3ae. It is with the SFP+ 20-pin connector to allow hot plug capability.
The FTCS-BXX1X-40XX module is designed for single mode fiber and operates at a nominal wavelength of 1270nm or 1330nm; The transmitter section uses a multiple quantum well DFB, which is class 1 laser compliant according to International Safety Standard IEC-60825.
The receiver section uses an integrated InGaAs detector preamplifier (IDP) mounted in an optical header and a limiting post-amplifier IC.
Electrical characteristics(TOP = 0 to 70¡æ£¬ VCC = 3.0 to 3.60 Volts)
Parameter |
Symbol |
Min. |
Typical |
Max |
Unit |
Ref. |
Supply Voltage |
VCC |
3.00 |
3.60 |
V |
1 |
|
Supply Current |
Icc |
200 |
300 |
mA |
1 |
|
Transmitter |
||||||
Input differential impedance |
Rin |
100 |
¦¸ |
2 |
||
Single ended data input swing |
Vin,pp |
150 |
1200 |
mVpp |
||
Transmit Disable Voltage |
VD |
2 |
VCC |
V |
||
Transmit Enable Voltage |
VEN |
Vee |
Vee+0.8 |
V |
3 |
|
Receiver |
||||||
Output differential impedance |
Rout |
100 |
¦¸ |
2 |
||
Single ended data output swing |
Vout,pp |
300 |
700 |
mV |
4 |
|
LOS Fault |
VLOS fault |
2 |
VCCHOST |
V |
5 |
|
LOS Normal |
VLOS norm |
Vee |
Vee+0.8 |
V |
5 |
Notes:
1. Module power consumption never exceeds 1W.
2. AC coupled.
3. Or open circuit.
4. Into 100 ohm differential termination.
5. LOS is LVTTL. Logic 0 indicates normal operation; logic 1 indicates no signal detected.
Pin Descriptions
Pin |
Symbol |
Name/Description |
1 |
VEET [1] |
Transmitter Ground |
2 |
Tx_FAULT [2] |
Transmitter Fault |
3 |
Tx_DIS [3] |
Transmitter Disable. Laser output disabled on high or open |
4 |
SDA [2] |
2-wire Serial Interface Data Line |
5 |
SCL [2] |
2-wire Serial Interface Clock Line |
6 |
MOD_ABS [4] |
Module Absent. Grounded within the module |
7 |
RS0 [5] |
RS0 for Rate Select: Open or Low = Module supports ¡Ü4.25Gbps High = Module supports 9.95 Gb/s to 10.3125 Gb/s |
8 |
RX_LOS [2] |
Loss of Signal indication. Logic 0 indicates normal operation |
9 |
RS1 [5] |
No connection required |
10 |
VEER [1] |
Receiver Ground |
11 |
VEER [1] |
Receiver Ground |
12 |
RD- |
Receiver Inverted DATA out. AC Coupled |
13 |
RD+ |
Receiver DATA out. AC Coupled |
14 |
VEER [1] |
Receiver Ground |
15 |
VCCR |
Receiver Power Supply |
16 |
VCCT |
Transmitter Power Supply |
17 |
VEET [1] |
Transmitter Ground |
18 |
TD+ |
Transmitter DATA in. AC Coupled |
19 |
TD- |
Transmitter Inverted DATA in. AC Coupled |
20 |
VEET [1] |
Transmitter Ground |
Notes:
[1] Module circuit ground is isolated from module chassis ground within the module.
[2].should be pulled up with 4.7k ¨C 10k ohms on host board to a voltage between 3.15Vand 3.6V.
[3]Tx_Disable is an input contact with a 4.7 k¦¸ to 10 k¦¸ pullup to VccT inside the module.
[4]Mod_ABS is connected to VeeT or VeeR in the SFP+ module. The host may pull this contact up to Vcc_Host with a resistor in the range 4.7 k¦¸ to10 k¦¸.Mod_ABS is asserted ¡°High¡± when the SFP+ module is physically absent from a host slot.
[5]RS0 and RS1 are module inputs and are pulled low to VeeT with > 30 k¦¸ resistors in the module.
Part No. | Description |
FTCS-B231X-40 | 1270nm/1330nm, 10Gbps, 40km, 0?C ~ +70?C |
FTCS-B321X-40 | 1330nm/1270nm, 10Gbps, 40km, 0?C ~ +70?C |
FTCS-B231X-40I | 1270nm/1330nm, 10Gbps, 40km, -40~+85¡æ |
FTCS-B321X-40I | 1330nm/1270nm, 10Gbps, 40km, -40~+85¡æ |