²úÆ·Ðͺţº(Â޽ܿµ¹âÄ£¿é:SFP1132-1BX10R¹âÄ£¿éÌæ»»ÐͺÅFTCS-B4312-20DI)
²úÆ·ÃèÊö£ºÂ޽ܿµSFP¹âÄ£¿é,SFP1132-1BX10R,1000BASEµ¥ÏËË«Ïò,10¹«Àï,T1490/R1310
¼æÈÝÆ·ÅÆ£ºRUGGEDCOM
Ô³§ÃèÊö£ºSiemens' RUGGEDCOM SFP1132-1BX10R 1000BASE-BX10-U SFP transceiver
Siemens' RUGGEDCOM SFP1132-1BX10R industrial grade 1 Gbps fiber optic bi-directional SFP transceiver operates within a wide temperature range (-40 to 85 ¡ãC or -40 to 185 ¡ãF) and provides high performance Gigabit Ethernet communication up to 10 km (6.2 mi) using single-mode fiber.
? Compliant with SFP MSA for 1000BASE-BX10-U
? Compliant with SFF-8472 Digital Diagnostic Monitoring Interface
? Transmission distance up to 10 km (6.2 mi)
? LC duplex fiber connector
? Bail latch
? Hot swappable
? RoHS compliant
Optical Characteristics
Transmit Power |
-9.0 to -3.0 dBm |
Receiver Sensitivity |
-19.5 to -3.0 dBm |
Power Budgeta |
10.5 db |
Cabling
Speed |
1000 Mbit/s |
Mode |
SM |
Interface |
BX |
Connector |
LC |
Cable Type (¦Ìm) |
9/125 |
Wavelength (Tx) |
1310 nm |
Wavelength (Rx) |
1490 nm |
Nominal Distance |
10 km (6.2 mi) |
Environment
Operating Temperature |
-40 to 85 ¡ãC (-40 to 185 ¡ãF) |
Operating Relative Humidity |
5 to 95% (non-condensing) |
Storage Temperature |
-40 to 85 ¡ãC (-40 to 185 ¡ãF) |
Assumes an SFP1132-1BX10T is used at the other end of the connection.
The RUGGEDCOM SFP1132-1BX10R meets the following standards when installed in Siemens RUGGEDCOM routers and/or switches:
Feature |
Standard |
Performance |
Electrostatic Discharge (ESD) to the Electrical Pins |
MIL-STD-883E, Method 3015.7 |
Class 1 |
Electrostatic Discharge (ESD) to the Duplex LC Receptacle |
IEC 61000-4-2 |
Compliant |
Electromagnetic Interference (EMI) |
FCC Part 15, Class B |
Compliant |
Laser Eye Safety |
US FDA 21CRF 1040.10 and 1040.11 IEC/EN 60825-1 and 60825-2 EN 60950 |
Compliant with Class I laser product |
RoHS |
EU RoHS Directive 2011/65/EU |
Compliant |
Article Number |
Name |
Description |
6GK6000-8FB51-0AA0 |
RUGGEDCOM SFP1132-1BX10R |
1000Base-BX SFP ¨C SM, 1310/1490 nm, LC, 40 km |
Important Notice
Performance figures, data and any illustrative material provided in this data sheet are typical and must bespecifically confirmed in writing by F-tone Networks before they become applicable to any particular order orcontract. In accordance with the F-tone Networks policy of continuous improvement specifications may changewithout notice. The publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.